Title 815 | Chapter 020 | Regulation 080


815 KAR 20:080.Waste pipe size.

Section 1.

The minimum size (nominal inside diameter) of traps, soil, or waste branches for a given fixture shall not be less than that established in the following table:

Minimum Size (in inches)

Fixture Unit

Trap

Branch

Automatic clothes washer

2

2

2

Basement floor drain

3

3

3

Bath: sitz

1 1/2

1 1/2

2

Bathtub

1 1/2

1 1/2

1 1/2

Combination fixture

2

2

2

Dental cuspidor

2

2

2

Dishwasher

1 1/2

1 1/2

1 1/2

Disposal unit

1 1/2

1 1/2

1 1/2

Drinking fountain

1 1/4

1 1/4

1

Floor drain in residential laundry room

2

2

2

Floor drain in toilet room

3

3

3

Floor drain in utility room

3

3

3

Industrial floor drain

4

4

4

Kitchen sink unit

1 1/2

1 1/2

1 1/2

Laundry tray

1 1/2

1 1/2

1 1/2

Lavatories

1 1/4

1 1/4

1

Santistand

3

4

6

Shower stall

1 1/2

1 1/2

1 1/2

Sink: bar or soda fountain

1 1/2

1 1/2

1 1/2

Sink: barium

2

2

2

Sink: chemical

1 1/2

1 1/2

1 1/2

Sink: clinic

3

4

6

Sink: kitchen, residence

1 1/2

1 1/2

1 1/2

Sink: plaster

2

2

2

Sink: service

3

3

3

Sink: service wall type

2

2

2

Sink: three compartment

2

2

2

Urinal: lip

1 1/2

1 1/2

1 1/2

Urinal: pedestal

3

3

3

Urinal: stall

2

2

2

Urinal: trough

1 1/2

1 1/2

1 1/2

Water closet: Greater than 1.6 gallons per flush

3

3 or 4

6

Water closet: 1.6 gallons per flush or less

3

3 or 4

4


HISTORY: (1 Ky.R. 481; eff. 3-12-1975; Recodified from 401 KAR 1:050, 7-5-78; Am. 9 Ky.R. 47; eff. 8-11-1982; TAm eff. 8-9-2007; 43 Ky.R. 460; eff. 11-16-2016; 46 Ky.R. 1667; eff. 6-2-2020.)

7-Year Expiration: 6/2/2027

Last Updated: 12/15/2021


Page Generated: 9/19/2024, 12:15:11 PM